Installations

40D Installation Instructions

ATTENTION

The Safe-T-Punch STP40D device is our industrial device. It is taller and heavier with a long stroke length and deeper penetration ability. It has found many uses where a larger device is preferred.

Although this device is extensively in-house tested, it is always recommended by ILR Safety that the installer performs suitability testing to their satisfaction. If in doubt please contact ILR Safety CC.

DISCLAIMER: –  
The manufacturer of Safe-T-Punch, ILR Safety CC does not accept any responsibility for incorrect installation and improper use of its products.

Some uses include:

  1. Retro-fitable to double glazed emergency windows previously equipped with hammers
  2. Double glazing assemblies with unknown toughened glass thickness
  3. Double glazing assemblies with an air gap of up to 20mm
  4. Thick toughened glass >10mm,
  5. Curved toughened glass, with heat strengthened concave surface (moulded toughened glass)
  6. Toughened glass of unspecified standard
  7. Toughened glass made under a different application standard.
  8. Toughened glass laminates
  9. Toughened foundry control room window assemblies.

The STP40D device can be OE fitted or retrofitted.

IMPORTANT NOTICE: – STP40D DOUBLE GLAZING INSTALLATIONN

A common application is for the retrofitting of existing double glazed toughened glass window assemblies. In this instance we make the following critical technical recommendation.

Please follow the standard Safe-T-Punch installation instructions AND include the directions below: –

Recommendation: – The STP40D device must be used in conjunction with a suitable film applied to the glass surface on the installation side. This serves to stabilise the installation.

Reason: – It prevents the device from becoming detached during activation in an emergency. Once the inner pane is broken the device may fall away with the broken glass before the outer pane is broken.

Film material: –  Anti-scratch film or window tinting film provides good results. Do NOT use on anti-graffiti film as this type shrugs-off adhesive when applied to it.

Film Suitability: – The film must be tested for ability to accept adhesive.

install pic1 1
chevron right

1

Apply this film edge to edge over the entire exposed interior surface of the emergency window’s glass pane in accordance with its manufacturer’s instructions.

install pic3
chevron right

2

Install the instructions sticker for the STP40D device onto the film.

install_pic2
chevron right

3

In the hole provided in the instructions sticker, cut a 16mm diameter disk  out of the centre and remove this piece of film.

install pic5
chevron right

4

Install the STP40D Device in the prepared area as per the standard  installation instructions for Safe-T-Punch devices.

30N, 40N, 40FA & 50FA Installation Instructions

ATTENTION

Only use on clearly marked toughened glass windows.

DO NOT use on laminate glass windscreens or any unmarked windows.
Minimum legal emergency exit window
size – 700mm x 500mm.

install pic1 1
chevron right

1

Clean interior surface of the emergency exit window using dishwashing liquid soap and water. Rinse using clean water and wipe dry with a clean paper towel.

install_pic2
chevron right

2

Read the warning instruction on the round cut-out of the sticker, once read, remove and discard this piece.

install pic3
chevron right

3

Apply the instruction decal at an appropriate position on the glass using an applicator squeegee or a plastic bank card. Any bubbles can be pricked with a pin and flattened by hand.

install_pic4
chevron right

4

Using the supplied alcohol swab carefully clean the exposed glass in the cut-out area on the instruction sticker. Do not rub the sticker with the swab supplied as this will remove the ink.

install pic5
chevron right

5

Peel off the adhesive backing from the Safe-T-Punch™ unit. Align the Safe-T-Punch™ centred to the cut-out in the instruction sticker with the safety tag in the vertical position.

install pic6
chevron right

6

Firmly press the Safe-T-Punch™ onto the glass and hold in position for thirty seconds.

Maintenance

ILR Safety recommends that the following maintenance be performed on every Safe-T-Punch installation.

INSPECTION

Daily:
Inspect installation for completeness and damage – Device, Safety Tag and Instructions Sticker

MAINTENANCE

Yearly:

  • Remove safety tag
  • Test device for free movement
  • Replace safety tag with new (All STP devices except STP50F)
  • Reinsert safety tag (STP50FA Devices)

ISO 9001:2015 Certification